| Image Sensor | 1/4” CMOS progressive scan. | |||
| AGC | Automatic and Manual. | |||
| WDR | >80Db. | |||
| Signal to Noise Ratio | >50dB. | |||
| Minimum Illumination | 20lux or IR flood lights providing even illumination required for smoke detection. Flame detection and thermopile are fully functional in complete darkness. | |||
| Compression | JPEG and MPEG-4. | |||
| Lens Options | Model / Lens | Range | Field of View | Operation |
| FVMD/500/2M4 | 10m* | 80⁰ x 60⁰ | Fixed | |
| FVMD/500/6M0 | 35m* | 34⁰ x 25⁰ | Fixed | |
| * Range reference distance based on 300mm x 300mm test pan burning 750ml fuel. Larger fires may be detected at greater range. | ||||
| Network Interface | IDC Punch-down Connectors. | |||
| Thermopile Specification | Field of View (degrees) | Resolution (pixels) | Temperature Range | |
| 6mm lens = 39⁰ / 2.4mm lens = 90⁰ | 80(h) x 64(v) | -20⁰C – 1000⁰C | ||
| Storage | Internal SD Card Integrated Recording (max 64GB). | |||
| Alarms and relays | 4 x non-polarised solid-state relay outputs provided. Outputs 1&2 capable of switching 600mA at 60V DC and configurable for Monitored Fire Alarm Loop. Outputs 3&4 capable of switching 2.2A @60V DC. 2 x Alarm inputs, logic level single ended. | |||
| Alarm Reporting | NetVu Connected Remote Alarm Reporting. | |||
| Analytics | Flame Detection. Smoke Detection. High /Low Temperature. | |||
| Network Protocols | NetVu Connected Advanced Streaming, NetVu Connected Remote Codec, DHCP, HTTP, HTTPS, Ipv4, SMTP, Bonjour, ICMP, DNS, NTP, TCP, UDP, ARP, RTSP/RTP Unicast and Multicast, Telnet, FTP, SNMP, Zeroconf, Modbus, MQTT. | |||
| Power | 12V DC, 24V DC and/or PoE. 4.5 Watts. |
| Ingress Protection Rating | IP66. |
| Operating Temperature | Operating: -10⁰C to 50⁰C. |
| Operating Humidity | 20% to 80% Relative Humidity (Non-Condensing). |
| Approvals | UKCA and CE marked. Complies with part 15 of FCC CFR47. RoHS Compliant. |
| Product Dimensions | 328mm x 269mm x 100mm. |
| Product Weight | 3.0kg. |